Home > Products >
Sand Processing Equipment
>
Sand Temperature Regulator Sand Cooling System with Circulating Water Cooling, Automated Temperature Control and Heat Exchange Drainage Pipes

Sand Temperature Regulator Sand Cooling System with Circulating Water Cooling, Automated Temperature Control and Heat Exchange Drainage Pipes

Product Details:
Place of Origin: Shandong, China
Brand Name: TOVAC
Model Number: 20t
Document: Sand Temperature Cooler.pdf
Detail Information
Place of Origin:
Shandong, China
Brand Name:
TOVAC
Model Number:
20t
Waterconsumption:
10-50 M³/h
Capacity:
10-100 Tons Per Hour
Function:
Vibrate The Casting Sand To Compaction
Dimensions:
Length 5-15m, Width 2-5m, Height 3-6m
Applicablematerials:
Sand, Gravel, Stone, Ore
Patternmakingmethod:
Foam Pattern Molding
Color:
Customizable
Noiselevel:
<85 DB
Installationtime:
2-3 Weeks
Automationlevel:
Semi-automatic/Automatic
Weight:
5-20 Tons
Highlight:

High Light

Highlight:

Circulating Water Cooling Sand Temperature Regulator

,

Automated Temperature Control Sand Cooling System

,

Heat Exchange Drainage Pipes Sand Temperature Regulator

Trading Information
Minimum Order Quantity:
1unit/set
Delivery Time:
10-20 working days
Payment Terms:
T/T
Supply Ability:
1000 units before the year
Product Description

1. Product Overview
The sand temperature regulator uses circulating water to cool or heat the sand material by ensuring full contact between the sand particles and the pipes inside the cooler, allowing for heat exchange to complete the cooling or heating task.

2. Components
The sand temperature regulator consists of several cooling sections, equipped with flow regulation plates and manual shut-off plates. Each cooling section contains multiple drainage pipes. The sand, after being air-classified, flows evenly through these cooling pipes, allowing it to cool down. The flow regulation plate consists of two layers of perforated plates, and the sand flow is controlled by adjusting the misalignment of the plates. The entire system uses automated control and is equipped with temperature sensors. After cooling, the sand temperature is fed back to the control center via the sensors for intermittent discharge.

3. Parameters

Production rate: ≥20~40T/h

Circulating water volume: 40~100 m³/h

Water pressure: 0.2-0.4Mpa

Cooling steel pipe: φ25×3

4. Main Functions and Advantages

Main Functions:

Reduce sand temperature to ensure molding quality

Stabilize production rhythm and improve efficiency

Pre-mix sand and homogenize temperature

Core Advantages:

Improve casting quality

Increase production efficiency

Heat energy recovery and environmental protection

Controllable automation